Uwb microwave power meter 40GHz detector RF power meter V8.0 TFT Display power meter V8 upper computer

£258.99
Categories:

Buy With Confidence

100% Safe Payment


;

  • Description

    I. Product Overview:


    The RF-Power-Meter V8.0 series is a high performance and low cost portable TYPE-C simple RF Power Meter. TYPE-C provides 5V power supply and high-speed data communication. Simple to use, small size, easy to carry, stable performance, high accuracy, preset bias, wide dynamic range, fast measurement speed. The software accompanying the power meter enables users to configure the power meter on the PC side and make data recording and sharing easy.


    RF-power-meter -V8.0 RF Power Meter Advantages:


    1, support a variety of high-speed dynamic acquisition, the maximum 500kbps(2uS) PC acquisition case;


    2, digital calibration display support 20GHz; The microwave detector supports up to 40GHz, and the data in the range of 20-40GHz can be displayed on TFT and output voltage through the aviation plug;


    3, power meter V7.0 comes with 1.3 inch TFT LCD and built-in Li battery, can run offline;


    4, the use of 5-port aviation plug to provide TTL serial port read and write function and analog detection output, to provide a single, continuous reading data mode.


    5, the host computer has two MARK cursor function, easy to measure the modulation pulse width; Automatically find the maximum value, the minimum value function; Maximum storage depth of 500 points; Supports pause, data saving, and export functions.


    6, RF input interface: 3.5mm SMA female head, stainless steel 40G interface.


    7, boot process: press the arrow key in the middle of the confirm button, and then long dial to the right for boot


    Shutdown process: Press and hold the confirm button in the middle of the arrow key.


    The preceding operations are performed when the battery switch is turned ON.


    product application:


    1. Calibration of RF instruments;


    2, RF equipment detection and maintenance;


    3, RF circuit standing wave ratio measurement (add feedback bridge);


    4, RF circuit return loss measurement;


    5, interference detection between wireless communication devices;


    6, RSSI (received signal strength indication) and transmit power level detection;


    7. Performance evaluation of stepping attenuator;


    8, amplifier gain and network attenuation measurement;


    9. Measurement of forward power and reflected power in directional coupler;


    10, using GMSK modulation of GSM signal power measurement *;




    product technical indicators:


    1, measuring power range -40 ~ +0dBm (0 to -30dbm has a good linearity);

    2, measuring power resolution ± 0.1dBm;

    3, the measurement frequency range of 100M ~ 40GHz(20-40GHz does not do digital calibration, only support analog display);

    4, input impedance: 50Ω;

    5, dynamic range :40dB;

    6, working voltage 5VDC (through the TYPE-C line power supply);

    7, charging current: 300mA;


    8, 66*36*24cm(excluding protruding N head, specific reference to the mechanical drawing given); The body is composed of a fully CNC aluminum alloy shell and weighs less than 100g.


    9. Shipping list: Host *1+TYPE-C line *1 with aluminum alloy shell.


    10, TFT display information description:


    Freq: Frequency setting, this data is a key input to calibrate the detection error at different frequencies, not the value measured by the power meter.


    Power: measured power unit W


    dBm is defined as miliwatt(milliwatt). 0 dBm=1mw;


    dBW defines watt. 0 dBW= 10lg1W= 10lg1000mw = 30dBm


    ATT: Numerical control attenuator value inside the power meter. Attenuation range: 0 to 31.75DB, the value needs to be set when measuring signals greater than 0 dBm, so that the measurement accuracy is better.


    Offset: indicates the value of the linear offset.


    The first function: when ATT is added, it needs to set the offset through the offset;


    The second function: calibrate interface error;


    Third function: If the external amplifier is added or there is a standard signal source, the relative error can be set by this value.


    95% internal lithium battery power indicates IC000 machine internal address